| | | |
| | | Termination Board for Honeywell Safety Manager | | FC-GPCD-SDI16-PF | | | | | | | | | | System Board for Honeywell SMS, For 16-channel card SDI-1624, 8 plug-in positions, Recommended module: HiC2822 (DI), 24 V DC supply voltage, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin | | | | | |
| | | Termination Board for Honeywell Safety Manager | | FC-GPCS-SDI16-PF | | | | | | | | | | System Board for Honeywell SMS, For 16-channel cards SDIL-1608 and SDI-1624, 16 plug-in positions, Recommended modules: HiC2821 (SIL2), HiC2851 (SIL3), 24 V DC supply voltage, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin | | | | | |
| | | Termination Board for Honeywell Safety Manager | | FC-GPCS-SDO08-PF | | | | | | | | | | System Board for Honeywell SMS, For 8-channel card SDO-0824, 8 plug-in positions, Recommended module: HiC2871 (DO), 24 V DC supply voltage, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin | | | | | |
| | | Termination Board for Honeywell Safety Manager | | FC-GPDD-SAI16-PF | | | | | | | | | | System Board for Honeywell SMS, For 16-channel card SAI-1620m, 8 plug-in positions, Recommended module: HiD2030 (AI), HiD2082 (Temp.), 24 V DC supply voltage, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin | | | | | |
| | | Honeywell GI/IS Termination Board | | HiCTB08-HON-0220-4S-PL | | | | | | | | | | System Board for Honeywell SMS, For 4 pieces 2-channel card SAO-0220m, 8 plug-in positions, Recommended module: HiC2031 (AO), 24 V DC supply voltage, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin | | | | | |
| | | Termination Board | | HiDTB08-TRI-AIISD-EL-PL | | | | | | | | | | System Board for Triconex (approval by Triconex pending), For 16-channel card 3703E, For 32-channel AI cards 3700, 3700A, 3701, and 3721, 8 plug-in positions, Recommended modules: HiD2026 (AI HART), HiD2030 (AI HART), 24 V DC supply voltage, Hazardous area: pluggable screw terminals, blue, Safe area: ELCO socket, 56-pin | | | | | |
| | | Termination Board | | HiDTB16-TRI-DIISQ-EL-SC | | | | | | | | | | System Board for Triconex (approval by Triconex pending), For 64-channel (32 32) DI cards 3504E and 3564, 16 plug-in positions, Recommended module: HiD2844 (DI), 24 V DC supply voltage, Hazardous area: screw terminals, blue, Safe area: ELCO socket, 56-pin | | | | | |
| | | Termination Board für Honeywell Experion Series C GI/IO | | SC-GPCD-DI32-PF | | | | | | | | | | System Board for Honeywell Experion PKS, Series C, For 32-channel card CC-TDIL01/11, 16 plug-in positions, Recommended module: HiC2822 (DI), Recommended system cable: CA-HWC300-AIO-DIO-*M, 24 V DC supply voltage, Hazardous area: pluggable screw terminals, blue, Safe area: Sub-D connector (male), 37-pin | | | | | |
| | | Termination Board für Honeywell Experion Series C GI/IO | | SC-GPCS-UNI16-PF | | | | | | | | | | System Board for Honeywell Experion PKS, Series C, For 16-/32-channel cards CC-TDIL01/11, CC-TDOB01/11, CC-TAIX01/11 and CC-TAOX01/11, 16 plug-in positions, Recommended modules: HiC2821 (DI), HiC2871 (DO), HiC2025 (AI), HiC2031 (AO), Recommended system cable: CA-HWC300-AIO-DIO-*M, 24 V DC supply voltage, Hazardous area: pluggable screw terminals, blue, Safe area: Sub-D connector (male), 37-pin | | | | | |
| | | Termination Board für Honeywell Experion Series C GI/IO | | SC-GPDD-AIO16-PF | | | | | | | | | | System Board for Honeywell Experion PKS, Series C, For 16-channel cards CC-TAIX01/11 (AI) and CC-TAOX01/11 (AO), 8 plug-in positions, Recommended modules: HiD2030SK (AI), HiD2081 (Temp.), HiD2032 (AO), Recommended system cable: CA-HWC300-AIO-DIO-*M, 24 V DC supply voltage, Hazardous area: pluggable screw terminals, blue, Safe area: Sub-D connector (male), 37-pin | | |